Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated voltage240 - 600V
Number of poles4
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Overload release current setting24.0 - 60A
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Rated permanent current Iu125A
Motor drive integratedNo
Integrated earth fault protectionYes
Adjustment range short-term delayed short-circuit release60 - 600A
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range undelayed short-circuit release60 - 600A
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075027R1 | XT2H 125 Ekip LSIG In=60A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated voltage

240 .. 600V

Number of poles

4

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Overload release current setting

24.0 .. 60A

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Rated permanent current Iu

125A

Motor drive integrated

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

60 .. 600A

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range undelayed short-circuit release

60 .. 600A

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.