  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Number of poles4
Rated voltage240 - 600V
Overload release current setting63.0 - 90A
Degree of protection (IP)IP20
Motor drive integratedNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
With switched-off indicatorNo
Motor drive optionalYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range undelayed short-circuit release450 - 900A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075248R1 | XT4H 250 TMA 90 450..900 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Rated voltage

240 .. 600V

Overload release current setting

63.0 .. 90A

Degree of protection (IP)

IP20

Motor drive integrated

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

With switched-off indicator

Motor drive optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range undelayed short-circuit release

450 .. 900A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release