Technical specifications

Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Overload release current setting87.5 - 125A
Position of connection for main current circuitFront side
Motor drive integratedNo
Number of poles4
Rated voltage240 - 600V
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release625 - 1250A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075285R1 | XT4L 250 TMA 125 625..1250 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Overload release current setting

87.5 .. 125A

Position of connection for main current circuit

Front side

Motor drive integrated

Number of poles

4

Rated voltage

240 .. 600V

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

With under voltage release

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

Adjustment range undelayed short-circuit release

625 .. 1250A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.