Technical specifications

Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
Overload release current setting24.0 - 60A
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release60 - 600A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Motor drive optionalYes
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release60 - 600A
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Rated permanent current Iu250A
Number of poles3
Rated voltage240 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075359R1 | XT4N 250 Ekip LS/I In=60A 3p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

Overload release current setting

24.0 .. 60A

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

60 .. 600A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Motor drive optional

With under voltage release

Adjustment range short-term delayed short-circuit release

60 .. 600A

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Rated permanent current Iu

250A

Number of poles

3

Rated voltage

240 .. 600V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA