Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Motor drive integratedNo
Position of connection for main current circuitFront side
Rated voltage240 - 600V
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Overload release current setting100.0 - 250A
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Number of poles4
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release250 - 2500A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release250 - 2500A
Motor drive optionalYes
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Integrated earth fault protectionNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075369R1 | XT4N 250 Ekip LS/I In=250A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Motor drive integrated

Position of connection for main current circuit

Front side

Rated voltage

240 .. 600V

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Overload release current setting

100.0 .. 250A

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Number of poles

4

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

250 .. 2500A

Motor drive optional

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Integrated earth fault protection

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.