Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu250A
Rated voltage240 - 600V
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Overload release current setting24.0 - 60A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
With switched-off indicatorNo
Adjustment range undelayed short-circuit release60 - 600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz35kA
DIN rail (top hat rail) mounting optionalYes
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release60 - 600A
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075371R1 | XT4S 250 Ekip LS/I In=60A 3p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

250A

Rated voltage

240 .. 600V

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Overload release current setting

24.0 .. 60A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

With switched-off indicator

Adjustment range undelayed short-circuit release

60 .. 600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

35kA

DIN rail (top hat rail) mounting optional

Motor drive integrated

Adjustment range short-term delayed short-circuit release

60 .. 600A

Device construction

Built-in device fixed built-in technique

Motor drive optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.