Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240 - 600V
Number of poles4
Position of connection for main current circuitFront side
Rated permanent current Iu250A
With switched-off indicatorNo
Overload release current setting100.0 - 250A
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz35kA
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release250 - 2500A
Adjustment range undelayed short-circuit release250 - 2500A
Motor drive optionalYes
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075381R1 | XT4S 250 Ekip LS/I In=250A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240 .. 600V

Number of poles

4

Position of connection for main current circuit

Front side

Rated permanent current Iu

250A

With switched-off indicator

Overload release current setting

100.0 .. 250A

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

35kA

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Adjustment range undelayed short-circuit release

250 .. 2500A

Motor drive optional

With under voltage release

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.