Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Degree of protection (IP)IP20
Number of poles4
Overload release current setting16.0 - 40A
With integrated under voltage releaseNo
Rated voltage240 - 600V
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release40 - 400A
Adjustment range short-term delayed short-circuit release40 - 400A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075388R1 | XT4L 250 Ekip LS/I In=40A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Degree of protection (IP)

IP20

Number of poles

4

Overload release current setting

16.0 .. 40A

With integrated under voltage release

Rated voltage

240 .. 600V

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Position of connection for main current circuit

Front side

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Motor drive optional

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range undelayed short-circuit release

40 .. 400A

Adjustment range short-term delayed short-circuit release

40 .. 400A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.