  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
Adjustment range short-term delayed short-circuit release250 - 2500A
Overload release current setting100.0 - 250A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
With under voltage releaseNo
Degree of protection (IP)IP20
With switched-off indicatorNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Adjustment range undelayed short-circuit release250 - 2500A
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Rated permanent current Iu250A
Number of poles4
Rated voltage240 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075393R1 | XT4L 250 Ekip LS/I In=250A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Overload release current setting

100.0 .. 250A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With under voltage release

Degree of protection (IP)

IP20

With switched-off indicator

Position of connection for main current circuit

Front side

Motor drive optional

Adjustment range undelayed short-circuit release

250 .. 2500A

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

250A

Number of poles

4

Rated voltage

240 .. 600V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.