  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu250A
Number of poles3
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Overload release current setting24.0 - 60A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Rated voltage240 - 600V
Type of control elementToggle
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release60 - 600A
Adjustment range undelayed short-circuit release60 - 600A
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075395R1 | XT4H 250 Ekip LS/I In=60A 3p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

250A

Number of poles

3

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Overload release current setting

24.0 .. 60A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Rated voltage

240 .. 600V

Type of control element

Toggle

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

60 .. 600A

Adjustment range undelayed short-circuit release

60 .. 600A

Degree of protection (IP)

IP20