Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Motor drive integratedNo
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu400A
Overload release current setting160.0 - 400A
Rated voltage600 - 600V
Type of control elementPush button
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP30
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release240.0 - 4000A
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Complete device with protection unitYes
Adjustment range undelayed short-circuit release600.0 - 6000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA077350R1 | E2.2V-A 400 Ekip Dip LSIG 3p F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Motor drive integrated

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

400A

Overload release current setting

160.0 .. 400A

Rated voltage

600 .. 600V

Type of control element

Push button

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP30

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

240.0 .. 4000A

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Complete device with protection unit

Adjustment range undelayed short-circuit release

600.0 .. 6000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.