Technical specifications

Voltage typeOther
Built-in depth70mm
Rated current2A
Frequency50 - 60Hz
Over voltage category3
Pollution degree2
Rated voltage240V
Current limiting class3
Rated insulation voltage Ui500V
Release characteristicB
Explosion-proofNo
Number of protected poles2
Connectable conductor cross section solid-core1 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Power loss2.2W
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section multi-wired1 - 10mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Width in number of modular spacings1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251281R0025 | S2011C-B2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

70mm

Rated current

2A

Frequency

50 .. 60Hz

Over voltage category

3

Pollution degree

2

Rated voltage

240V

Current limiting class

3

Rated insulation voltage Ui

500V

Release characteristic

B

Explosion-proof

Number of protected poles

2

Connectable conductor cross section solid-core

1 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Power loss

2.2W

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section multi-wired

1 .. 10mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV