Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Concurrently switching neutral conductorNo
Release characteristicB
Number of poles (total)2
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated voltage240V
Rated insulation voltage Ui500V
Voltage typeAC
Rated current6A
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Current limiting class3
Additional equipment possibleYes
Over voltage category3
Pollution degree2
Connectable conductor cross section solid-core1 - 16mm²
Connectable conductor cross section multi-wired1 - 10mm²
Built-in depth17.8mm
Width in number of modular spacings1
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251281R0065 | S2011C-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Release characteristic

B

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated voltage

240V

Rated insulation voltage Ui

500V

Voltage type

AC

Rated current

6A

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Current limiting class

3

Additional equipment possible

Over voltage category

3

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 16mm²

Connectable conductor cross section multi-wired

1 .. 10mm²

Built-in depth

17.8mm

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.