Technical specifications

Current limiting class3
Release characteristicC
Rated insulation voltage Ui500V
Voltage typeAC
Rated voltage415V
Frequency50 - 60Hz
Rated current2A
Built-in depth17.8mm
Width in number of modular spacings1
Over voltage category3
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 16mm²
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 10mm²
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0024 | S202C-C2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Release characteristic

C

Rated insulation voltage Ui

500V

Voltage type

AC

Rated voltage

415V

Frequency

50 .. 60Hz

Rated current

2A

Built-in depth

17.8mm

Width in number of modular spacings

1

Over voltage category

3

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 16mm²

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 10mm²

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.