Technical specifications

Voltage typeAC
Built-in depth17.8mm
Release characteristicC
Pollution degree2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Connectable conductor cross section solid-core1 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated voltage415V
Current limiting class3
Degree of protection (IP)IP20
Rated current10A
Number of protected poles2
Over voltage category3
Width in number of modular spacings1
Suitable for flush-mounted installationNo
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 10mm²
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0104 | S202C-C10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

17.8mm

Release characteristic

C

Pollution degree

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

1 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated voltage

415V

Current limiting class

3

Degree of protection (IP)

IP20

Rated current

10A

Number of protected poles

2

Over voltage category

3

Width in number of modular spacings

1

Suitable for flush-mounted installation

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 10mm²

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.