Aleta.hr
Main Product Image

2CDS252280R0165 | S202C-B16

Code: 1989625

ManufacturerABB
Catalog number2CDS252280R0165
EAN code4053546044737

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Release characteristicB
Rated voltage415V
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated current16A
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated insulation voltage Ui500V
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Over voltage category3
Pollution degree2
Current limiting class3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Suitable for flush-mounted installationNo
Width in number of modular spacings1
Built-in depth17.8mm
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 10mm²
Connectable conductor cross section solid-core1 - 16mm²
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0165 | S202C-B16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Release characteristic

B

Rated voltage

415V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated current

16A

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Over voltage category

3

Pollution degree

2

Current limiting class

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Suitable for flush-mounted installation

Width in number of modular spacings

1

Built-in depth

17.8mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 10mm²

Connectable conductor cross section solid-core

1 .. 16mm²

Ambient temperature during operating

-25 .. 55°C