Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Release characteristicB
Number of protected poles2
Rated current25A
Rated voltage415V
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Current limiting class3
Voltage typeAC
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Frequency50 - 60Hz
Pollution degree2
Over voltage category3
Built-in depth17.8mm
Degree of protection (IP)IP20
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Width in number of modular spacings1
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core1 - 16mm²
Connectable conductor cross section multi-wired1 - 10mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0255 | S202C-B25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Release characteristic

B

Number of protected poles

2

Rated current

25A

Rated voltage

415V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Current limiting class

3

Voltage type

AC

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Frequency

50 .. 60Hz

Pollution degree

2

Over voltage category

3

Built-in depth

17.8mm

Degree of protection (IP)

IP20

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

1 .. 16mm²

Connectable conductor cross section multi-wired

1 .. 10mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.