Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Release characteristicC
Number of protected poles2
Number of poles (total)2
Rated voltage415V
Rated insulation voltage Ui500V
Rated current32A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Current limiting class3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Width in number of modular spacings1
Frequency50 - 60Hz
Ambient temperature during operating-25 - 55°C
Over voltage category3
Suitable for flush-mounted installationNo
Built-in depth17.8mm
Connectable conductor cross section multi-wired1 - 10mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Voltage typeAC
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0324 | S202C-C32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Release characteristic

C

Number of protected poles

2

Number of poles (total)

2

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated current

32A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Current limiting class

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Width in number of modular spacings

1

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Suitable for flush-mounted installation

Built-in depth

17.8mm

Connectable conductor cross section multi-wired

1 .. 10mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Voltage type

AC

Pollution degree

2