Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated current40A
Built-in depth17.8mm
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 16mm²
Connectable conductor cross section multi-wired1 - 10mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Ambient temperature during operating-25 - 55°C
Release characteristicC
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Additional equipment possibleYes
Width in number of modular spacings1
Pollution degree2
Number of protected poles2
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Number of poles (total)2
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated voltage415V
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252280R0404 | S202C-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

40A

Built-in depth

17.8mm

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 16mm²

Connectable conductor cross section multi-wired

1 .. 10mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 .. 55°C

Release characteristic

C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Additional equipment possible

Width in number of modular spacings

1

Pollution degree

2

Number of protected poles

2

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated voltage

415V

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.