Technical specifications

Built-in depth17.6mm
Voltage typeAC
Rated current6A
Width in number of modular spacings1
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated voltage240V
Concurrently switching neutral conductorYes
Rated insulation voltage Ui500V
Connectable conductor cross section multi-wired1.5 - 16mm²
Release characteristicB
Pollution degree2
Power loss2.2W
With interlocking deviceNo
Connectable conductor cross section solid-core1.5 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of protected poles1
Frequency50/60 Hz
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
Surge current capacity-kA
Rated fault current0.03A
Over voltage category3
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Leakage current typeAC
Number of poles (total)2
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255063R1065 | DS301C B6 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

17.6mm

Voltage type

AC

Rated current

6A

Width in number of modular spacings

1

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated voltage

240V

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Connectable conductor cross section multi-wired

1.5 .. 16mm²

Release characteristic

B

Pollution degree

2

Power loss

2.2W

With interlocking device

Connectable conductor cross section solid-core

1.5 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of protected poles

1

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

Surge current capacity

-kA

Rated fault current

0.03A

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Leakage current type

AC

Number of poles (total)

2

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA