Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Width70mm
With control elementYes
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Number of digital inputs4
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for ASINo
With optical interfaceNo
Number of HW-interfaces RS-4851
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for KNXNo
Number of HW-interfaces other1
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Number of analogue inputs1
Depth143mm
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUSNo
Height209mm
Number of digital outputs2
With PC connectionYes
Integrated breaking resistanceNo
4-quadrant operation possibleNo
Number of interfaces PROFINET0
Degree of protection (IP)IP20
Application in domestic- and commercial area permittedYes
Supporting protocol for other bus systemsNo
Type of converterU converter
Mains frequency50/60 Hz
Number of phases output3
Max. output frequency599Hz
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNetNo
Number of phases input1
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
Mains voltage200 - 240V
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Max. output voltage240V
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Nominal output current I2N4.8A
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ACS180-04S-04A8-1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Width

70mm

With control element

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Number of digital inputs

4

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for ASI

With optical interface

Number of HW-interfaces RS-485

1

Supporting protocol for CAN

Supporting protocol for LON

Supporting protocol for KNX

Number of HW-interfaces other

1

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Number of analogue inputs

1

Depth

143mm

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS

Height

209mm

Number of digital outputs

2

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

Application in domestic- and commercial area permitted

Supporting protocol for other bus systems

Type of converter

U converter

Mains frequency

50/60 Hz

Number of phases output

3

Max. output frequency

599Hz

Supporting protocol for SERCOS

Supporting protocol for DeviceNet

Number of phases input

1

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

Mains voltage

200 .. 240V

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

0.75kW

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Max. output voltage

240V

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Nominal output current I2N

4.8A

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

From same serie

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.