Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated voltage230V
Built-in depth82.5mm
Rated current80A
Current limiting class3
Rated insulation voltage Ui690V
Release characteristicB
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core1 - 70mm²
Additional equipment possibleYes
Number of poles (total)1
Number of protected poles1
Flush-mounted installationNo
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Over voltage category3
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Width in number of modular spacings1.5
Power loss6.4W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001214R0001 | S801P-B80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated voltage

230V

Built-in depth

82.5mm

Rated current

80A

Current limiting class

3

Rated insulation voltage Ui

690V

Release characteristic

B

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

Number of poles (total)

1

Number of protected poles

1

Flush-mounted installation

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Over voltage category

3

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Width in number of modular spacings

1.5

Power loss

6.4W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.