Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Frequency50 - 60Hz
Degree of protection (IP)IP20
Explosion-proofNo
Release characteristicB
Rated insulation voltage Ui690V
Number of protected poles3
Width in number of modular spacings4.5
Number of poles (total)3
Rated voltage400V
Current limiting class3
Over voltage category3
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Flush-mounted installationNo
Rated current100A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Pollution degree3
Power loss24W
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 70mm²
Rated impulse withstand voltage Uimp6kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired1 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001221R0001 | S803P-B100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Explosion-proof

Release characteristic

B

Rated insulation voltage Ui

690V

Number of protected poles

3

Width in number of modular spacings

4.5

Number of poles (total)

3

Rated voltage

400V

Current limiting class

3

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Rated current

100A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Pollution degree

3

Power loss

24W

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 70mm²

Rated impulse withstand voltage Uimp

6kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

1 .. 50mm²