Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Current limiting class3
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Power loss32W
Number of protected poles4
Number of poles (total)4
Frequency50 - 60Hz
Rated current100A
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Width in number of modular spacings6
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001224R0001 | S804P-B100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Current limiting class

3

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Power loss

32W

Number of protected poles

4

Number of poles (total)

4

Frequency

50 .. 60Hz

Rated current

100A

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

6

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.