Technical specifications

Rated voltage230V
Number of protected poles1
Built-in depth82.5mm
Rated current100A
Number of poles (total)1
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp6kV
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Release characteristicC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V4.5kA
Current limiting class3
Frequency50 - 60Hz
Power loss8W
Additional equipment possibleYes
Over voltage category3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings1.5
Connectable conductor cross section multi-wired1 - 50mm²
Flush-mounted installationNo
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core1 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001227R0001 | S801P-C100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Number of protected poles

1

Built-in depth

82.5mm

Rated current

100A

Number of poles (total)

1

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Current limiting class

3

Frequency

50 .. 60Hz

Power loss

8W

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

1 .. 50mm²

Flush-mounted installation

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

1 .. 70mm²