Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Current limiting class3
Release characteristicC
Width in number of modular spacings4.5
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated insulation voltage Ui690V
Built-in depth82.5mm
Additional equipment possibleYes
Power loss19.2W
Frequency50 - 60Hz
Rated voltage400V
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 50mm²
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Over voltage category3
Rated impulse withstand voltage Uimp6kV
Number of poles (total)3
Rated current80A
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001232R0001 | S803P-C80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Current limiting class

3

Release characteristic

C

Width in number of modular spacings

4.5

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Additional equipment possible

Power loss

19.2W

Frequency

50 .. 60Hz

Rated voltage

400V

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 50mm²

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Over voltage category

3

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

3

Rated current

80A

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

From same serie