Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp6kV
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui690V
Number of protected poles4
Frequency50 - 60Hz
Rated voltage400V
Power loss25.4W
Built-in depth82.5mm
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current80A
Voltage typeOther
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Explosion-proofNo
Width in number of modular spacings6
Pollution degree3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001235R0001 | S804P-C80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

690V

Number of protected poles

4

Frequency

50 .. 60Hz

Rated voltage

400V

Power loss

25.4W

Built-in depth

82.5mm

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

80A

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Explosion-proof

Width in number of modular spacings

6

Pollution degree

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.