Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Release characteristicD
Built-in depth82.5mm
Rated voltage230V
Number of poles (total)1
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Power loss6.4W
Current limiting class3
Additional equipment possibleYes
Over voltage category3
Degree of protection (IP)IP20
Width in number of modular spacings1.5
Pollution degree3
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 70mm²
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001238R0001 | S801P-D80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Release characteristic

D

Built-in depth

82.5mm

Rated voltage

230V

Number of poles (total)

1

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Power loss

6.4W

Current limiting class

3

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Pollution degree

3

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²