Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui690V
Release characteristicD
Voltage typeOther
Built-in depth82.5mm
Rated current80A
Frequency50 - 60Hz
Current limiting class3
Rated voltage400V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings4.5
Over voltage category3
Power loss19.2W
Number of protected poles3
Connectable conductor cross section solid-core1 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Explosion-proofNo
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section multi-wired1 - 50mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001244R0001 | S803P-D80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Release characteristic

D

Voltage type

Other

Built-in depth

82.5mm

Rated current

80A

Frequency

50 .. 60Hz

Current limiting class

3

Rated voltage

400V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

4.5

Over voltage category

3

Power loss

19.2W

Number of protected poles

3

Connectable conductor cross section solid-core

1 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Explosion-proof

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section multi-wired

1 .. 50mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.