Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Number of protected poles3
Release characteristicD
Number of poles (total)3
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current100A
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui690V
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Power loss24W
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Width in number of modular spacings4.5
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
Connectable conductor cross section multi-wired1 - 50mm²
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001245R0001 | S803P-D100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of protected poles

3

Release characteristic

D

Number of poles (total)

3

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

100A

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

690V

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

24W

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Connectable conductor cross section multi-wired

1 .. 50mm²

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.