Technical specifications

Number of poles (total)3
Release characteristicD
Number of protected poles3
Rated voltage400V
Built-in depth82.5mm
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current125A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Frequency50 - 60Hz
Current limiting class3
Power loss28.2W
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Additional equipment possibleYes
Width in number of modular spacings5
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001246R0001 | S803P-D125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

D

Number of protected poles

3

Rated voltage

400V

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

125A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

28.2W

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Additional equipment possible

Width in number of modular spacings

5