Aleta.hr
Main Product Image

2CCG001247R0001 | S804P-D80

Code: 1996943

ManufacturerRAZNO
Catalog number2CCG001247R0001
Type
EAN code7612271517168

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

82.5mm

Release characteristic

D

Rated insulation voltage Ui

690V

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 - 60Hz

Power loss

25.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Flush-mounted installation

No

Pollution degree

3

Over voltage category

3

Additional equipment possible

Yes

Concurrently switching neutral conductor

No

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 - 70mm²

Connectable conductor cross section multi-wired

1 - 50mm²

Explosion-proof

No

Ambient temperature during operating

-25 - 60°C


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001247R0001 | S804P-D80

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

82.5mm

Release characteristic

D

Rated insulation voltage Ui

690V

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

25.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Flush-mounted installation

Pollution degree

3

Over voltage category

3

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 70mm²

Connectable conductor cross section multi-wired

1 .. 50mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.