Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Frequency50 - 60Hz
Rated current100A
Built-in depth82.5mm
Voltage typeOther
Rated insulation voltage Ui690V
Release characteristicD
Width in number of modular spacings6
Over voltage category3
Pollution degree3
Current limiting class3
Number of protected poles4
Power loss32W
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core1 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)4
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001248R0001 | S804P-D100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Frequency

50 .. 60Hz

Rated current

100A

Built-in depth

82.5mm

Voltage type

Other

Rated insulation voltage Ui

690V

Release characteristic

D

Width in number of modular spacings

6

Over voltage category

3

Pollution degree

3

Current limiting class

3

Number of protected poles

4

Power loss

32W

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

1 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

4

Explosion-proof

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.