Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Number of poles (total)2
Built-in depth82.5mm
Rated current80A
Number of protected poles2
Rated impulse withstand voltage Uimp6kV
Voltage typeOther
Release characteristicK
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Power loss12.8W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Ambient temperature during operating-25 - 60°C
Pollution degree3
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
Additional equipment possibleYes
Degree of protection (IP)IP20
Flush-mounted installationNo
Over voltage category3
Connectable conductor cross section multi-wired1 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001253R0001 | S802P-K80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Number of poles (total)

2

Built-in depth

82.5mm

Rated current

80A

Number of protected poles

2

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Release characteristic

K

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Power loss

12.8W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Width in number of modular spacings

3

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

Degree of protection (IP)

IP20

Flush-mounted installation

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.