Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current100A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Number of protected poles2
Rated impulse withstand voltage Uimp6kV
Frequency50 - 60Hz
Current limiting class3
Number of poles (total)2
Built-in depth82.5mm
Release characteristicK
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss16W
Rated voltage400V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated insulation voltage Ui690V
Flush-mounted installationNo
Pollution degree3
Explosion-proofNo
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Width in number of modular spacings3
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001254R0001 | S802P-K100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

100A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of protected poles

2

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Current limiting class

3

Number of poles (total)

2

Built-in depth

82.5mm

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

16W

Rated voltage

400V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated insulation voltage Ui

690V

Flush-mounted installation

Pollution degree

3

Explosion-proof

Additional equipment possible

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

3

Degree of protection (IP)

IP20