Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current125A
Over voltage category3
Current limiting class3
Rated insulation voltage Ui690V
Built-in depth82.5mm
Explosion-proofNo
Frequency50 - 60Hz
Degree of protection (IP)IP20
Power loss37.6W
Release characteristicK
Voltage typeOther
Rated voltage400V
Width in number of modular spacings6.5
Pollution degree3
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 70mm²
Number of protected poles4
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001261R0001 | S804P-K125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

125A

Over voltage category

3

Current limiting class

3

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Explosion-proof

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Power loss

37.6W

Release characteristic

K

Voltage type

Other

Rated voltage

400V

Width in number of modular spacings

6.5

Pollution degree

3

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 70mm²

Number of protected poles

4

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.