Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Rated current80A
Rated voltage400V
Rated impulse withstand voltage Uimp6kV
Built-in depth82.5mm
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)2
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Voltage typeOther
Power loss12.8W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui690V
Release characteristicB
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 70mm²
Width in number of modular spacings3
Flush-mounted installationNo
Degree of protection (IP)IP20
Pollution degree3
Connectable conductor cross section multi-wired1 - 50mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001266R0001 | S802P-B80-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Rated current

80A

Rated voltage

400V

Rated impulse withstand voltage Uimp

6kV

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Voltage type

Other

Power loss

12.8W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

690V

Release characteristic

B

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

3

Flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.