Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicK
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Rated voltage400V
Frequency50 - 60Hz
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Voltage typeOther
Power loss12.8W
Rated insulation voltage Ui690V
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
Width in number of modular spacings3
Over voltage category3
Connectable conductor cross section multi-wired1 - 50mm²
Concurrently switching neutral conductorNo
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001269R0001 | S802P-K80-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Frequency

50 .. 60Hz

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Voltage type

Other

Power loss

12.8W

Rated insulation voltage Ui

690V

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Concurrently switching neutral conductor

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20