Aleta.hr
Main Product Image

2CCG001269R0001 | S802P-K80-R

Code: 1996965

ManufacturerRAZNO
Catalog number2CCG001269R0001
Type
EAN code7612271517380

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Frequency

50 - 60Hz

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Voltage type

Other

Power loss

12.8W

Rated insulation voltage Ui

690V

Flush-mounted installation

No

Ambient temperature during operating

-25 - 60°C

Explosion-proof

No

Connectable conductor cross section solid-core

1 - 70mm²

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section multi-wired

1 - 50mm²

Concurrently switching neutral conductor

No

Pollution degree

3

Additional equipment possible

Yes

Degree of protection (IP)

IP20


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001269R0001 | S802P-K80-R

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Frequency

50 .. 60Hz

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Voltage type

Other

Power loss

12.8W

Rated insulation voltage Ui

690V

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 50mm²

Concurrently switching neutral conductor

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20