Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated current80A
Number of protected poles3
Rated insulation voltage Ui690V
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Voltage typeOther
Current limiting class3
Number of poles (total)3
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Power loss19.2W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 70mm²
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 50mm²
Degree of protection (IP)IP20
Flush-mounted installationNo
Over voltage category3
Width in number of modular spacings4.5
Ambient temperature during operating-25 - 60°C
Pollution degree3
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001270R0001 | S803P-B80-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

80A

Number of protected poles

3

Rated insulation voltage Ui

690V

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Current limiting class

3

Number of poles (total)

3

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Power loss

19.2W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 50mm²

Degree of protection (IP)

IP20

Flush-mounted installation

Over voltage category

3

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.