Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Concurrently switching neutral conductorNo
Number of protected poles4
Degree of protection (IP)IP20
Power loss25.4W
Width in number of modular spacings6
Current limiting class3
Release characteristicK
Frequency50 - 60Hz
Rated current80A
Rated insulation voltage Ui690V
Voltage typeOther
Pollution degree3
Built-in depth82.5mm
Over voltage category3
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 50mm²
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001277R0001 | S804P-K80-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Concurrently switching neutral conductor

Number of protected poles

4

Degree of protection (IP)

IP20

Power loss

25.4W

Width in number of modular spacings

6

Current limiting class

3

Release characteristic

K

Frequency

50 .. 60Hz

Rated current

80A

Rated insulation voltage Ui

690V

Voltage type

Other

Pollution degree

3

Built-in depth

82.5mm

Over voltage category

3

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 50mm²

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA