Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Rated insulation voltage Ui690V
Built-in depth82.5mm
Number of protected poles1
Number of poles (total)1
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Voltage typeOther
Rated current100A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V4.5kA
Frequency50 - 60Hz
Current limiting class3
Power loss8W
Release characteristicD
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired1 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001280R0001 | S801P-D100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Number of protected poles

1

Number of poles (total)

1

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

Other

Rated current

100A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

8W

Release characteristic

D

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

1 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.