Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Rated current100A
Over voltage category3
Release characteristicK
Frequency50 - 60Hz
Current limiting class3
Pollution degree3
Rated insulation voltage Ui690V
Rated voltage230V
Width in number of modular spacings1.5
Connectable conductor cross section solid-core1 - 70mm²
Power loss8W
Degree of protection (IP)IP20
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section multi-wired1 - 50mm²
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V4.5kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Additional equipment possibleYes
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)1
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001281R0001 | S801P-K100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Rated current

100A

Over voltage category

3

Release characteristic

K

Frequency

50 .. 60Hz

Current limiting class

3

Pollution degree

3

Rated insulation voltage Ui

690V

Rated voltage

230V

Width in number of modular spacings

1.5

Connectable conductor cross section solid-core

1 .. 70mm²

Power loss

8W

Degree of protection (IP)

IP20

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Additional equipment possible

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

1

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.