Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proofNo
Rated insulation voltage Ui690V
Pollution degree3
Release characteristicC
Rated current100A
Rated voltage400V
Frequency50 - 60Hz
Number of protected poles2
Current limiting class3
Built-in depth82.5mm
Over voltage category3
Voltage typeOther
Power loss16W
Degree of protection (IP)IP20
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Connectable conductor cross section solid-core1 - 70mm²
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated impulse withstand voltage Uimp6kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001283R0001 | S802P-C100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proof

Rated insulation voltage Ui

690V

Pollution degree

3

Release characteristic

C

Rated current

100A

Rated voltage

400V

Frequency

50 .. 60Hz

Number of protected poles

2

Current limiting class

3

Built-in depth

82.5mm

Over voltage category

3

Voltage type

Other

Power loss

16W

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Connectable conductor cross section solid-core

1 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated impulse withstand voltage Uimp

6kV

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA