Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Voltage typeOther
Rated current100A
Frequency50 - 60Hz
Built-in depth82.5mm
Pollution degree3
Rated insulation voltage Ui690V
Width in number of modular spacings6
Release characteristicC
Current limiting class3
Over voltage category3
Power loss32W
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 70mm²
Number of protected poles4
Number of poles (total)4
Connectable conductor cross section multi-wired1 - 50mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001291R0001 | S804P-C100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Voltage type

Other

Rated current

100A

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Pollution degree

3

Rated insulation voltage Ui

690V

Width in number of modular spacings

6

Release characteristic

C

Current limiting class

3

Over voltage category

3

Power loss

32W

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 70mm²

Number of protected poles

4

Number of poles (total)

4

Connectable conductor cross section multi-wired

1 .. 50mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.