Technical specifications

Voltage typeOther
Rated current100A
Rated voltage400V
Release characteristicD
Over voltage category3
Rated insulation voltage Ui690V
Current limiting class3
Frequency50 - 60Hz
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Ambient temperature during operating-25 - 60°C
Number of protected poles4
Connectable conductor cross section multi-wired1 - 50mm²
Width in number of modular spacings6
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Pollution degree3
Power loss32W
Connectable conductor cross section solid-core1 - 70mm²
Degree of protection (IP)IP20
Explosion-proofNo
Number of poles (total)4
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001292R0001 | S804P-D100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

100A

Rated voltage

400V

Release characteristic

D

Over voltage category

3

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

4

Connectable conductor cross section multi-wired

1 .. 50mm²

Width in number of modular spacings

6

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Pollution degree

3

Power loss

32W

Connectable conductor cross section solid-core

1 .. 70mm²

Degree of protection (IP)

IP20

Explosion-proof

Number of poles (total)

4

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.