Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Release characteristicK
Frequency50 - 60Hz
Rated current100A
Built-in depth82.5mm
Rated voltage400V
Pollution degree3
Power loss32W
Over voltage category3
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Current limiting class3
Explosion-proofNo
Width in number of modular spacings6
Connectable conductor cross section multi-wired1 - 50mm²
Connectable conductor cross section solid-core1 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001293R0001 | S804P-K100-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Release characteristic

K

Frequency

50 .. 60Hz

Rated current

100A

Built-in depth

82.5mm

Rated voltage

400V

Pollution degree

3

Power loss

32W

Over voltage category

3

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Current limiting class

3

Explosion-proof

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.