Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Number of poles (total)3
Rated current125A
Number of protected poles3
Built-in depth82.5mm
Voltage typeOther
Release characteristicB
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Current limiting class3
Power loss28.2W
Concurrently switching neutral conductorNo
Explosion-proofNo
Pollution degree3
Width in number of modular spacings5
Connectable conductor cross section multi-wired1 - 50mm²
Over voltage category3
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001302R0001 | S803P-B125-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Number of poles (total)

3

Rated current

125A

Number of protected poles

3

Built-in depth

82.5mm

Voltage type

Other

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Power loss

28.2W

Concurrently switching neutral conductor

Explosion-proof

Pollution degree

3

Width in number of modular spacings

5

Connectable conductor cross section multi-wired

1 .. 50mm²

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.