Technical specifications

Rated impulse withstand voltage Uimp6kV
Rated current125A
Rated voltage400V
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Release characteristicC
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)3
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui690V
Number of protected poles3
Power loss28.2W
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Flush-mounted installationNo
Over voltage category3
Pollution degree3
Connectable conductor cross section solid-core1 - 70mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 50mm²
Width in number of modular spacings5
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001303R0001 | S803P-C125-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

6kV

Rated current

125A

Rated voltage

400V

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Release characteristic

C

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

690V

Number of protected poles

3

Power loss

28.2W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Flush-mounted installation

Over voltage category

3

Pollution degree

3

Connectable conductor cross section solid-core

1 .. 70mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 50mm²

Width in number of modular spacings

5