Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current125A
Power loss37.6W
Rated voltage400V
Degree of protection (IP)IP20
Pollution degree3
Rated insulation voltage Ui690V
Voltage typeOther
Release characteristicK
Explosion-proofNo
Number of protected poles4
Width in number of modular spacings6.5
Connectable conductor cross section solid-core1 - 70mm²
Current limiting class3
Over voltage category3
Ambient temperature during operating-25 - 60°C
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Connectable conductor cross section multi-wired1 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)4
Rated impulse withstand voltage Uimp6kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG001309R0001 | S804P-K125-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

125A

Power loss

37.6W

Rated voltage

400V

Degree of protection (IP)

IP20

Pollution degree

3

Rated insulation voltage Ui

690V

Voltage type

Other

Release characteristic

K

Explosion-proof

Number of protected poles

4

Width in number of modular spacings

6.5

Connectable conductor cross section solid-core

1 .. 70mm²

Current limiting class

3

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Built-in depth

82.5mm

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

6kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.