Aleta.hr
Main Product Image

2CDS381001R0014 | S301P-C1

Code: 1997048

ManufacturerABB
Catalog number2CDS381001R0014
EAN code4016779080675

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Rated voltage240V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Voltage typeOther
Power loss1.4W
Release characteristicC
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class-
Rated insulation voltage Ui500V
Rated current1A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Built-in depth69mm
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Over voltage category4
Pollution degree3
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Width in number of modular spacings1.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0014 | S301P-C1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Rated voltage

240V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Voltage type

Other

Power loss

1.4W

Release characteristic

C

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

-

Rated insulation voltage Ui

500V

Rated current

1A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Built-in depth

69mm

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Width in number of modular spacings

1.0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.